Setaflash Series 8 Activecool Flash Point Tester


Part No. 82100-0

POA
OR

Quick Overview

Setaflash Series 8 Activecool Flash Point Tester

PDF Downloads

Setaflash Series 8 Activecool Flash Point Tester

More Views

  • Setaflash Series 8 Activecool Flash Point Tester

Product Description

The Setaflash Series 8 'ActiveCool' is an automated closed cup flash point tester with a temperature range of 10 to 130°C (50 to 266°F) with no external cooling required. When connected to a suitable chilled water supply, the range is extended down to -20°C (-4°F).

There are two modes of operation; Flash / No Flash and Ramp. The ramp mode increases the sample temperature at a rate of 2°C/min and automatically dips the ignitor every 1°C up to 100°C (every 2°C above 100°C), until either a flash is detected or the end of test temperature is reached.

ADDITIONAL INFORMATION

The automatic flash point detection system is tuned to ignore halo and other false flash effects, enhancing precision and accuracy. Barometric pressure is measured by an internal barometer, and the correction is automatically applied to the test result.

Peltier cell technology is used for heating and cooling, ensuring precise temperature control and rapid cooldown after a test is completed. The ignitor uses a new electrical hot wire (for the gas option see 82110-0). The bright colour LCD display shows test parameters and the flash point test result. The text and colour of the top line indicates instrument status. All functions are accessed via menus, navigated by the keypad. Up to 64 test results can be stored in memory, each tagged with a sample reference and operator name. Results can be downloaded to a PC or printer via the RS232C port (USB or LAN ports options available). The firmware is upgradeable for future developments.

SUPPLIED WITH:
  • Ignitor
  • 2ml syringe
  • mains lead
  • instruction manual.

SPECIFICATIONS
  • Temperature Range: Air: 10 to 130°C (50 to 266°F) Water Assisted: -20 to 130°C (-4 to 266°F) using 99300-2
  • Sample Size: 2 or 4ml according to method
  • Ignitor: Electrical Hot Wire (For Gas option see 82110-0)
  • Test duration, Rapid Equilibrium Mode: 1 minute below 100°C, 2 minutes above 100°C, FAME 1 minute or user defined 1 to 99 minutes
  • Test duration, Ramp Mode: Typically 7 minutes
  • Cool Down Time: 80 to 20°C (176 to 68°F) in 4 minutes
  • Sample Cup Material: Aluminium
  • Heating / Cooling Method: Peltier Cell
  • Computer Interface: RS232C (USB & LAN options)
  • Voltage: 100 to 250V, 50/60Hz (2x AA dry cell batteries required for internal clock)
  • Power: 300W (maximum)
  • Size (HxWxD): 30 x 34 x 38cm
  • Weight: 8kg
  • CCCN Code: Tariff 90268020
  • METHODS: ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 3900 Part A13, BS 6664 Parts 3 & 4, CHIPS Regulations, EPA 1020 A & B, IP 523, IP 524, IP 534, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids

DETAILS OF METHODS:

CHIPS Regulations:
Chemicals Hazard Information and Packaging for Supply

EPA 1020 A & B
Setaflash Closed-Cup Method for determining ignitability

ASTM D3828
Standard Test Methods for Flash Point by Small Scale Closed Tester

ASTM D3278
Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - The test methods are applicable to paints, enamels, lacquers, varnishes, and related products having a flash point between 0 and 110°C (32 and 230°F) and Viscosity lower than 150 St at 25°C (77°F).

ISO 3680
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)

UN Class 3 Non-viscous Flammable Liquids
Small scale flash point testers are universally specified in many international regulations to define and classify "flammable" and "combustible" substances.

ASTM E502
Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods

ISO 3679
Determination of flash point. Rapid equilibrium closed cup method

BS 6664 Parts 3 & 4
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (closed cup equilibrium method)

BS 3900 Part A13
Test for flash/no flash (rapid equilibrium method)

IP 523
Determination of flash point. Rapid equilibrium closed cup method

IP 524
Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)

ASTM D7236
Flash Point by Small Scale Closed Cup Ramp Method

IP 534
Flash Point by Small Scale Closed Cup Ramp Method

Additional Information

Country of ManufactureUnited Kingdom
Dimensions cm (WxDxH)(HxWxD): 30 x 34 x 38cm
Hazardous Product?No
ManufacturerStanhope Seta
Tarriff Code90268020
Gross Weight (Kg)8.8000