Setaflash Series 3 Open Cup Flash Point Tester


Part No. 31000-0

POA
OR

Quick Overview

Setaflash Series 3 Open Cup Flash Point Tester

PDF Downloads

Setaflash Series 3 Open Cup Flash Point Tester

More Views

  • Setaflash Series 3 Open Cup Flash Point Tester

Product Description

 The Setaflash Series 3 Open Cup Flash Point Tester is an easy to use instrument for flash/no flash, finite determinations or sustained combustion tests. Similar in design to the 30000-0 Setaflash 3, the instrument allows testing at any specific temperature within a range of ambient to 300°C.

ADDITIONAL INFORMATION

A manually operated flame sweeping arm is fitted to the cup of the Series 3 flash point tester and gas is supplied from the integral tank via the control valve. The flash or sustained combustion characteristics of the sample are observed visually by passing the test flame over the sample.

Supplied with: 2ml syringe, igniter, test flame height gauge, mains lead, and instruction manual.

SPECIFICATIONS

  Description
Temperature range Ambient to 300°C
Sample Size 2ml
Test time 2 minutes for flash points between 100° to 300°C 2 minutes for flash points between 100° to 300°C
Default values Default values: 1 minute for flash points up to 100°C 2 minutes for flash points between 100° to 300°C
Cup Material Blackened Aluminium
Voltage 110/120V or 220/240V, 50/60Hz (switchable) or 12V using optional power supply
Size (HxWxD) 25.6 x 28 x 25.6cm
Weight 4kg
CCCN Code: Tariff 90268020

 

FEATURES

  • Flash point test in less than 2 minutes
  • Small sample size - 2ml
  • Audible and on-screen prompts
  • Portable operation
  • Simple calibration


METHODS

ASTM D4206, BS 3900 Part A11, CFR 49-173.120, Health & Safety Comm. Carriage of Dangerous Goods by Road & Rail App B, IATA Dangerous Goods Regs. Section 3.3.5, ISO 9038, UN Class 3 Test L2

DETAILS OF METHODS

Method Description
ASTM D4206 Sustained Burning of Liquid Mixtures by setaflash Tester (Open Cup)
BS 3900 Part A11 Small scale test for combustibility
UN Class 3 Test L2 Certain substances classified as Flammable by Closed Cup Flash Point Testing may be reclassified as non-flammable by combustibility testing.
CFR 49-173.120 Ability of Liquid Paints to Sustain Combustion (Open Cup)
IATA Dangerous Goods Regs. Section 3.3.5 Ability of Liquid Paints to Sustain Combustion (Open Cup)
Health & Safety Comm. Carriage of Dangerous Goods by Road & Rail App B Ability of Liquid Paints to Sustain Combustion (Open Cup)
ISO 9038 Flash Point

Additional Information

Country of ManufactureUnited Kingdom
Dimensions cm (WxDxH)(HxWxD): 25.6 x 28 x 25.6cm
Hazardous Product?No
ManufacturerStanhope Seta
Tarriff Code90268020
Gross Weight (Kg)4.9500