Seta Multiflash Cleveland Flash Point Tester


Part No. 34300-2

POA
OR

Quick Overview

Seta Multiflash Cleveland Flash Point Tester

PDF Downloads

Seta Multiflash Cleveland Flash Point Tester

More Views

  • Seta Multiflash Cleveland Flash Point Tester

Product Description

 Seta Multiflash is an automatic Cleveland flash point tester, the 34300-2 Cleveland module is used with the 34000-0 MultiFlash Universal Base unit.

The module conforms precisely to national and international Cleveland open cup flash point test methods. It comprises a sample cup, temperature probe, flash/fire detector, and a DIPS pod (Sweeping, Ignition, Pilot, Stirrer) containing the ignitor sweeping mechanism with co-axial gas/electric ignitor.

Interchanging the test module is straight forward and completed in just a few minutes, the base unit recognises that the Cleveland module is connected and instantaneously sets up standard test parameters and calibration data.

ADDITIONAL INFORMATION

The flash point Test Area consists of a removeable sample cup in a thermal insulation ring, and a probe block for mounting the flash / fire detector and sample temperature probe. The sample cup is heated by the hotplate within the 34000-0 Universal Base Unit.

The DIPS pod contains the ignitor sweeping mechanism with a coaxial gas jet / electric hot wire ignitor, and a snuffer that extinguishes any flames in the sample cup at the end of the test. The sample temperature probe is a class A PRT, and flash / fire detection is by an ionisation ring.

Safety features include an initial sweep to check that the sample is below its flash point at the start of the test and a PRT check to ensure that the correct probe is connected and is immersed in sample. When in search mode, the software limits the maximum temperature to 50°C above "expected flash". The snuffer automatically deploys at the end of the test or if the independant fire detection probe (mounted over the test area) detects a flame. The hotplate in the 34000-0 is equipped with a cut-out to protect against over-temperature.

The optional 34008-0 Cooling Boost Module allows the test area to be rapidly cooled in between tests by a blast of compressed air.

Supplied with: DIPS pod, Test Area, Ignitor, Flash / Fire Detector, Sample PRT, interconnection leads, and instruction manual. Note: 34000-0 Universal Base Unit required for operation.

SPECIFICATIONS

  • Temperature Range: Ambient to 400°C
  • Heating: Hotplate
  • Post Test Cooling: Fan assisted or Forced Air (Requires 34008-0 Cooling Boost Module option)
  • Post Test Cool-down Time (90°C to 50°C): 9 minutes (Fan) 6 minutes (Forced Air)
  • Ignitor: Quick-fit coaxial gas jet / electric hot wire, user selectable (Electric hot wire pilot light for gas jet)
  • Temperature Probe: Class A Platinum Resistance Thermometer, °C or °F
  • Flash / Fire Detection: Ionisation Ring
  • Gas Supply (gas jet ignitor): Laboratory gas, 3kPa (0.44psi) maximum pressure
  • Air Supply (forced air cooling): Dry compressed air, 670kPa (100psi) maximum pressure
  • Voltage: 110/120V or 220/240V, 50/60Hz, (switchable)
  • Power: 1kW
  • Size (HxWxD): 34 x 45 x 42cm
  • Weight: 20kg
  • CCCN Code: Tariff 90268020

FEATURES

  • Fully self-contained flash/fire point test module
  • Exactly conforms to the requirement of Cleveland test method
  • Automatic set up of test parameters
  • Gas or electric ignition
  • Automatic heating control, ignition & flash/fire detection
  • Automatic test results & end of test audible warning
  • Automatic snuffer
  • Centigrade or Fahrenheit temperature display
  • Automatic barometric correction

METHODS

AASHTO T48, ASTM D92, BS 2000 Parts 36 & 403 (obs), DIN 51 376, EN ISO 2592, IP 36, JIS K2265, NF T60-119

DETAILS OF METHODS

  • DIN 51 376: Flash And Fire Points by Cleveland Open Cup
  • AASHTO T48: Flash Point
  • NF T60-119: Cone Penetration of Petroleum
  • JIS K2265: The Multiflash-PM fully automates and conforms precisely to national and international Pensky- Martens Closed Cup standard test methods.
  • ASTM D92: Standard test method for flash and fire points by cleveland open cup
  • IP 36: Determination of flash and fire points - Cleveland open cup method (ISO 2592:2000)
  • EN ISO 2592: Flash Point
  • BS 2000 Parts 36 & 403 (obs): Flash point

Additional Information

Country of ManufactureUnited Kingdom
Dimensions cm (WxDxH)(HxWxD): 47 x 42 x 34cm
Hazardous Product?No
ManufacturerStanhope Seta
Tarriff Code90268020
Gross Weight (Kg)20.0000